I went to move the cart this morning to get cleaned up to sell, just my luck it wouldn't move. Solenoid was clicking but no go. I wiggled the wires on top of the alltrax axe4865 and finally got it to go. After washing the cart, again it will not move. The solenoid clicks and the led blinks 4 times and goes to solid green. So I went by the troubleshooting guide and with my positive probe on the black ITS wire and negative probe on the battery pack negative I get 9.9 volts, if I unhook the wire and check voltage at the controller pin I get 14 volts. Does this sound like the ITS is the culprit?
↧